Suitable current | to 15A |
---|---|
Measuring accuracy | ±1% |
Linearity | 1.5% |
Withstand voltage | AC1,000V/for 1 minute (between core and lead) |
Insulation resistance | DC500V/100MΩ or higher (between core and lead) |
Power supply voltage | +5V±0.5% |
Current consumption | 10mA or less |
Operating temperature range | -10 to 60 [℃] |
Remarks | * RoHS compliant * External diameter of accommodated wiring: φ3.2 to 4.6 (wiring with conductor diameters of φ1.6/2.0/2.6 accommodated) * The specifications here are suitable for utility frequencies (50/60Hz) |